Spill Prevention Control & Countermeasures2026-08-31T11:50:03-05:00

Spill Prevention and Control Countermeasures (SPCC) Plans and Site Inspection Reports

Determining jurisdictional oversight, completing initial SPCC Plans, conducting ongoing site inspections and ensuring SPCC Plans stay up to date with the Waters of the U.S. definitions required for every company with oil storage. Depending on how many sites you operate or how complex those sites are, this can be a time-consuming, burdensome task.

Altamira has the experienced professionals to help relieve your company personnel of these tasks, freeing them up to focus on other aspects of your business. Our team is experienced in preparing Oil Spill Contingency Plans and Facility Response Plans (FRPs) for EPA, U.S. Coast Guard and PHMSA jurisdictional regulations.

an oil refinery with a large spherical tank in the foreground.

SPCC Plans – Altamira’s experienced staff will collect and/or verify information during site visits, compile the information into a SPCC Plan that complies with federal, state and any applicable local regulations. Altamira will have the plan reviewed and certified by a Professional Engineer with prompt delivery to you in your preferred manner. Altamira has completed SPCC Plans for upstream, midstream and downstream energy companies; the food and beverage industry; industrial, municipal and manufacturing sectors; electrical substations; and refineries, petrochemical and bulk storage facilities.

SPCC Inspection Reports – Using a cloud-based platform, Altamira is capable of conducting site inspections, uploading equipment details and photos and signing off on site inspection completion from the field. Site inspection reports are then generated, which display the data collected in an organized manner.

Customize Your Data – Let Altamira know what additional information you would like us to collect while on-site, and we can add it to the field inspection form. Examples include tank manufacturer, serial numbers and year, heater treater BTU rating and number of pneumatic pumps on-site, among others.

What Makes Altamira Your Competitive Advantage?

We understand that data gathered as part of maintaining SPCC compliance has additional value for other aspects of your operation, such as verifying air permit information, completing annual Tier II reports, confirming on-site signage is correct and compliant and ensuring equipment inventories are accurate. Developed from our owner’s mentality and holistic approach, Altamira’s Site Inspection Report solves this disconnect by collecting and delivering all of the critical information in an organized manner as part of each SPCC Plan.

Our mission at Altamira is to solve our clients’ most complex regulatory, operational and business challenges by being the first choice and trusted partner for strategy, consulting, technical expertise and digital technology solutions.

For more details, download our SPCC Plans and Site Inspection brochure.

Download Brochure
a staircase is leading up to a row of tan tanks.

Frequently Asked Questions About Spill Prevention and Control Countermeasures

How does Altamira help with SPCC Plan development and compliance?2026-08-31T11:48:59-05:00

Altamira prepares new SPCC Plans and updates existing plans for oil and gas facilities, terminals, refineries and industrial sites. Their licensed professional engineers conduct site assessments, evaluate secondary containment adequacy, develop inspection and testing procedures, facilitate staff training and certify plans to meet EPA requirements. They also assist with agency inspections and plan amendments following spill events.

What are the secondary containment requirements under SPCC regulations?2026-08-31T11:48:35-05:00

Secondary containment must have sufficient capacity to hold the contents of the largest single tank within the containment area, plus additional freeboard for precipitation. Acceptable secondary containment includes berms, dikes, retaining walls and equivalent measures constructed of impervious materials. The SPCC rule provides specific capacity calculations and construction requirements for different containment types.

How often must an SPCC Plan be reviewed and updated?2026-08-31T11:47:50-05:00

SPCC Plans must be reviewed every five years and updated whenever there is a change in facility design, construction, operation or maintenance that affects the potential for an oil spill or the spill prevention countermeasures. Plans must also be amended within six months after a spill or near-miss that reveals a deficiency in the plan.

Which facilities are required to have an SPCC Plan?2026-08-31T11:47:36-05:00

Facilities that store, use or handle oil in any form above regulatory threshold quantities are required to have an SPCC Plan if they could reasonably be expected to discharge oil to navigable waters or adjoining shorelines. Thresholds are 1,320 gallons in aboveground containers or 42,000 gallons total underground. Most oil and gas facilities, refineries, terminals and industrial plants with fuel storage qualify.

What is a Spill Prevention, Control, and Countermeasure (SPCC) Plan?2026-08-31T11:47:21-05:00

A Spill Prevention, Control and Countermeasure (SPCC) Plan is an EPA-required document under 40 CFR Part 112 that outlines how a facility will prevent oil spills from reaching navigable waters or adjoining shorelines. The plan covers facility description, secondary containment measures, inspection and testing schedules, personnel training and spill response procedures. It must be certified by a licensed professional engineer.

Empower Your Next Project With Altamira’s Expertise

Whether you need air quality compliance support for a chemical processing plant or are building a new manufacturing facility, you need an experienced partner to ensure positive outcomes. Let Altamira’s expert team bolster decision-making and empower your facility to overcome challenges efficiently. We offer support to clients throughout the U.S.

Contact us today to discuss your industrial or commercial project.

Go to Top